JWF LK 20 Leak Calibrator
  
 
For quick precise checking, adjustment and calibration of leak testers.

Small and handy, light and independent of mains, the LK 20 is suitable for quick and precise calibration in production and for quality control:

  • Direct display of leakage rate in cm³/min
     
  • Instantly available result of measurement
     
  • Measured value independent of atmospheric pressure and temperature
     
  • Suitable for high pressure and vacuum leak testers
 
Mode of operation

The JWF FROEHLICH LK 20 leak calibrator works by the air mass flow rate measuring method. The adjustable precision restrictor is simply connected to the quick-action coupling of the leak tester. The leaking air flows directly to the sensor. The leakage rate set at the restrictor is immediately displayed as the mass flow rate digitally in cm³/min on the LCD.
 
 
Technical data  
Measuring method

Measuring range


Resolution




Dimension
 

Weight
 

Power Supply

Scope of supply

mass flow monitoring

-20 bis + 20 Norm cm³/min
switchable from -100 to +100 Norm cm³/min

0,01 Norm cm³/min at measuring range -20 to +20 Norm cm³/min
0,1 Norm cm³/min at measuring range -100 to +100 Norm cm³/min

calibrator approx. 160 x 90 x 45 mm
case approx. 380 x 330 x 90 mm

calibrator approx. 0,3 kg
case approx. 1,75 kg

with battery and charger

Leak calibrator with precision restrictor and fitting for quick-action coupling, connecting pieces, battery with charger and operating instruction.